您的位置: 首頁 > 技術(shù)文章 > Acrel anti-backflow meter apply in the Philippines photovoltaic project

Acrel anti-backflow meter apply in the Philippines photovoltaic project

更新日期:2021-11-09瀏覽:605次

1.Background

    With the development of photovoltaic industry, the capacity of village-level transformers and industrial power transformers and the installed capacity of photovoltaic projects are saturated in some areas.The power grid company requires the photovoltaic grid-connected system to be a non-backflow current generation system, which means that the electricity generated by the photovoltaic grid-connected system is consumed by the local load, and the excess electricity is not allowed to be sent to the upper power grid through the low-voltage distribution transformer in reverse direction.

    Photovoltaic inverter in photovoltaic components will produce direct current into alternating current (ac), has the dc component and harmonic mixing, unbalanced three phase current, output power of uncertainty, such as the current basic didn't take effective management measures, therefore, when there is power to the utility grid, will generate harmonic pollution to power network, easy cause power grid voltage fluctuation and flicker, etc.,If there are many such power sources to transmit electricity to the grid, the power quality of the grid will be seriously degraded.Therefore, this kind of photovoltaic power generation system must be equipped with anti-backflow current facilities to prevent the occurrence of reverse power.

    When the photovoltaic power generation is greater than the load demand, the inverse power will be generated.So we need instruments to determine that Inverter has power output, and then by the instrument through RS485 communication signal and inverter data interaction, adjust the inverter output power, so that its output power and power balance.

2.Project Overview

    A photovoltaic power generation company in the Philippines contacted our company to look for anti-backflow current meters. After proper connection agreement, we will purchase ACR10R-D16TE from our company.

3.Anti-backflow detection meter

    When the photovoltaic power generation is greater than the load demand, reverse power will be generated. Therefore, we need an meter to determine that the inverter has over-power output, and then the meter sends a signal through RS485 communication to interact with the inverter data to adjust the output power of the inverter to balance the output power and the electrical power.

1.png

4.Function 

2.png

4.png

5.Wiring


6.Typical Connection

7.png

Bibliography

1.Solutions for enterprise micro-grid system 


 

Contact Us
  • 郵箱:2885080326@qq.com
  • 地址:上海市嘉定區(qū)育綠路253號

掃一掃  微信咨詢

©2025 安科瑞電氣股份有限公司 版權(quán)所有    備案號:滬ICP備05031232號-79    技術(shù)支持:智慧城市網(wǎng)    Sitemap.xml    總訪問量:201726    管理登陸

電瓶車充電樁禁止非法改裝

精品久久香蕉国产线看观看亚洲,躁BBB躁BBB躁BBBBBB,成人乱码一区二区三区AV,精品无码三级在线观看视频 免费AV在线| 大又大粗又爽又黄少妇毛片| 男JI大巴进入女人的视频66M| 把腿扒开让我添30分钟视频| 国产AV一区二区三区传媒| 国产特级毛片AAAAAA| 国产农村乱辈无码| 狂乳乱人伦| 国产真实露脸乱子伦原著| 久久ER99热精品一区二区| 欧洲裸体XXXXX毛片D女| 欧美精品一区二区少妇免费A片| 69久久国产露脸精品国产| 午夜亚洲AV永久无码精品| 欧洲多毛裸体XXXXX| 久久亚洲AV成人无码| 亚洲日韩一区二区| 少妇无力反抗慢慢张开双腿| 欧美又大又粗无码视频| 国产草草影院CCYYCOM| 中文字幕亚洲无线码在线一区| 国产性猛交╳XXX乱大交| 无码AV免费毛片一区二区| 无码AV中文一区二区三区桃花岛| 日本精品无码特级毛片| 久久亚洲AV无码精品色午夜麻豆 | 国产精品videossex国产高清| 色欲AV蜜桃一区二区三| 精品无码一区二区三区| JUL-965毕业典礼之后| 一本一道AⅤ无码中文字幕| 国产综合精品| 国产偷人爽久久久久久老妇APP| 偷拍孕妇做受| 韩国三级巜双乳紧扣| 亚洲中文字幕无码AV永久| 强壮公借种日日躁我| 色一情一区二区三区四区| av片在线观看免费| 欧美顶级毛片在线播放| 中文字字幕在线中文无码|